GRAPHIX TWO

Part Number: 230681V01

Contact us for availability

Click For Availability

GRAPHIX

Universal 1 to 3 channel display and operating unit with persistent display of all measurement channels, suited for the active sensors of the THERMOVAC, CERAVAC, linear sensors (DU series), PENNINGVAC and IONIVAC series.

Connectable Sensors

 

THERMOVAC

TTR 211 / TTR 216 S; TTR 90 / TTR 91 / TTR 91 N; TTR 96 S / TTR 96 N S; TTR 100 / TTR 100 S2; TTR 101 / TTR 101 N / TTR 101 S2 / TTR 101 N 2S; TTR 911 / TTR 911 N; TTR 916 / TTR 916 N

 

CERAVAC

CTR 90 / CTR 91; CTR 100 / CTR 100 N; CTR 101 / CTR 101 N

 

Linear pressure sensors

DU 200 / DU 201; DU 2000 / DU 2001; DU 2001 rel.

 

PENNINGVAC

PTR 90 / PTR 90 N; PTR 225 / PTR 225 N; PTR 225 S / PTR 225 N S; PTR 237 / PTR 237 N

 

IONIVAC

ITR 90 / ITR 90 N; ITR 200 S / ITR 200 N S; ITR 200 N SL

 

Other brands

Active sensors with linear or logarithmic output

Features and Benefits

  • Display range from 1 x 10-10 to 2000 mbar.
  • 3.5" touch screen display with intuitive menu interface.
  • Graphic display of the measurement data.
  • Internal and external (front side USB) storing of measurement data and configuration files.
  • Leak rate indication based on the pressure rise method.
  • 6 adjustable variable hysteresis switching thresholds, floating changeover contacts and visual indication of the switching status in the display area, freely assignable to the individual measurement channels.
  • Different visualisation options (graphs and decimal display with zoom function).
  • For connection of all active sensors of other brands.
  • Degas function for ITR transmitters
  • Zero alignment for CTR transmitters

General Product Information

Dimension Comments The dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models.
Product Title Part Number Add to cart
CERAVAC CTR 101 - DN 16 ISO-KF 1000Torr 230320V01
CERAVAC CTR 101 - DN 16 ISO-KF 100Torr 230321V01
CERAVAC CTR 101 - DN 16 ISO-KF 10Torr 230322V01
CERAVAC CTR 101 - DN 16 ISO-KF 1Torr 230323V01
CERAVAC CTR 101 - DN 16 ISO-KF 0.1Torr 230324V01
CERAVAC CTR 101 - DN 16 CF-R 1000Torr 230325V01
CERAVAC CTR 101 - DN 16 CF-R 100Torr 230326V01
CERAVAC CTR 101 - DN 16 CF-R 10Torr 230327V01
CERAVAC CTR 101 - DN 16 CF-R 1Torr 230328V01
CERAVAC CTR 101 - DN 16 CF-R 0.1Torr 230329V01
CERAVAC CTR 101 - Cajon 8VCR 1000Torr 230330V01
CERAVAC CTR 101 - Cajon 8VCR 100Torr 230331V01
CERAVAC CTR 101 - Cajon 8VCR 10Torr 230332V01
CERAVAC CTR 101 - Cajon 8VCR 1Torr 230333V01
CERAVAC CTR 101 - Cajon 8VCR 0.1Torr 230334V01
CERAVAC CTR 101 - 1/2" tube 1000Torr 230335V01
CERAVAC CTR 101 - 1/2" tube 100Torr 230336V01
CERAVAC CTR 101 - 1/2" tube 10Torr 230337V01
CERAVAC CTR 101 - 1/2" tube 1Torr 230338V01
CERAVAC CTR 101 - 1/2" tube 0.1Torr 230339V01
CERAVAC CTR 100 - DN 16 ISO-KF 1000Torr 230300V01
CERAVAC CTR 100 - DN 16 ISO-KF 100Torr 230301V01
CERAVAC CTR 100 - DN 16 ISO-KF 10Torr 230302V01
CERAVAC CTR 100 - DN 16 ISO-KF 1Torr 230303V01
CERAVAC CTR 100 - DN 16 KF CDG 0.1Torr 230304V01
CERAVAC CTR 100 - DN 16 CF-R 1000Torr 230305V01
CERAVAC CTR 100 - DN 16 CF-R 100Torr 230306V01
CERAVAC CTR 100 - DN 16 CF-R 10Torr 230307V01
CERAVAC CTR 100 - DN 16 CF-R 1Torr 230308V01
CERAVAC CTR 100 - DN 16 CF CDG 0.1Torr 230309V01
CERAVAC CTR 100 - Cajon 8-VCR 1000Torr 230310V01
CERAVAC CTR 100 - Cajon 8-VCR 100Torr 230311V01
CERAVAC CTR 100 - Cajon 8-VCR 10Torr 230312V01
CERAVAC CTR 100 - Cajon 8-VCR 1Torr 230313V01
CERAVAC CTR 100 - 8VCR CDG 0.1Torr 230314V01
CERAVAC CTR 100 - 1/2" tube 1000Torr 230315V01
CERAVAC CTR 100 - 1/2" tube 100Torr 230316V01
CERAVAC CTR 100 - 1/2" tube 10Torr 230317V01
CERAVAC CTR 100 - 1/2" tube 1Torr 230318V01
CERAVAC CTR 100 - DN 16 KF CDG 20Torr 230340V01
DU 201 - Absolute Pressure Sensor - DN 16 ISO-KF 230501V01
DU 2001 - Absolute Pressure Sensor - DN 16 ISO-KF 230503V01
DU 2001 - Pressure Sensor relative - DN 16 ISO-KF 230504V01
DU 2000 - Absolute Pressure Sensor - DN 16 ISO-KF 230502V01
DU 200 - Absolute Pressure Sensor - DN 16 ISO-KF 230500V01
PENNINGVAC PTR 90 RN - DN 25 KF 23L0021100
PENNINGVAC PTR 90 RN - DN 40 KF 23L0031100
PENNINGVAC PTR 90 RN - DN 40 CF 23L0041100
PENNINGVAC PTR 90 RNS - DN 25 KF 23L0121100
PENNINGVAC PTR 90 RNS - DN 40 KF 23L0131100
PENNINGVAC PTR 90 RNS - DN 40 CF 23L0141100
PENNINGVAC PTR 225 RN - DN 25 KF 22L0021100
PENNINGVAC PTR 225 RN - DN 40 KF 22L0031100
PENNINGVAC PTR 225 RN - DN 40 CF 22L0041100
THERMOVAC TTR 91 RN - DN 16 ISO-KF 21L1011100
THERMOVAC TTR 91 RN - DN 16 ISO-KF - (G - Matched Inficon 1.9-10 V) 21L1011120
THERMOVAC TTR 91 RN - DN 16 ISO-KF - (O - Matched Pfeiffer 2.2 - 8.5 V) 21L1011130
THERMOVAC TTR 91 RN - DN 16 ISO-KF - (Q - Matched MKS) 21L1011140
THERMOVAC TTR 91 RN - DN 25 ISO-KF 21L1021100
THERMOVAC TTR 91 RN - 1/8" NPT 21L1051100
THERMOVAC TTR 91 RN - 1/8" NPT - (G - Matched Inficon 1.9-10 V) 21L1051120
THERMOVAC TTR 91 RN - DN 16 CF 21L1091100
THERMOVAC TTR 91 RNS - DN 16 ISO-KF 21L1211100
THERMOVAC TTR 91 RNS - DN 16 ISO-KF - (G - Matched Inficon 1.9-10 V) 21L1211120
THERMOVAC TTR 91 RNS - DN 25 ISO-KF 21L1221100
THERMOVAC TTR 91 RNS - DN 25 ISO-KF - (G - Matched Inficon 1.9-10 V) 21L1221120
THERMOVAC TTR 91 RNS - 1/8" NPT 21L1251100
THERMOVAC TTR 91 RNS - DN 16 CF 21L1291100
THERMOVAC TTR 96 RN - DN 16 ISO-KF 21L2011100
THERMOVAC TTR 96 RN - DN 16 ISO-KF - G 21L2011120
THERMOVAC TTR 96 RN - DN 25 ISO-KF 21L2021100
THERMOVAC TTR 96 RNS - DN 16 ISO-KF 21L2211100
THERMOVAC TTR 96 RNS - DN 25 ISO-KF 21L2221100
THERMOVAC TTR 96 RNS - DN 16 CF 21L2291100
THERMOVAC TTR 97 RN - DN 16 ISO-KF 21L3011100
THERMOVAC TTR 97 RN - DN 25 ISO-KF 21L3021100
THERMOVAC TTR 97 RN - DN 16 CF 21L3091100
THERMOVAC TTR 97 RNS - DN 16 ISO-KF 21L3211100
THERMOVAC TTR 97 RNS - DN 25 ISO-KF 21L3221100