Specifications

Power Total Rated 30000.00

RUVAC WA40000 B IEC ATEX CAT. 2 INT T2

Part Number: 1495040KV01CJL

Contact us for availability

Click For Availability

General Product Information

Dimension Height 0.990
Dimension Length 1.70
Dimension Width 0.400
Leak Rate 5.000 × 10⁻⁴
Noise / Sound Level 80.00 db(A)
Weight 2088.00
Dimension Comments The dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models.
Connection Inlet / Outlet Flange DN 500 PN6 | DN 250 ISO-F
Certification of Product CE
RoHS

Performance Data

Power Total Rated 30000.00
Power Total Rated @50Hz 30000.00
Pressure Differential Max 2500.00
Nominal rotational speed 66.00
Minimum Roatational Speed 9.00
Maximum Rotational Speed 66.00

Environmental Conditions

Temperature Ambient Operation Max 40.00
Temperature Ambient Storage Max 80.00
Temperature Ambient Operation Min -20.00
Temperature Ambient Storage Min -20.00

Operation Conditions - Limitations

Altitude Max 3000.00
Flow Cooling Water Min 2.778 × 10⁻³
Lubricant Capacity Max 7.000 × 10⁻³
Temperature Cooling Water Max 40.00
Temperature Cooling Water Min 5.00
Temperature Inlet Gas Max 60.00

Classification

Classification Dry or Wet Pump Dry

Material of Construction

Material Rotor SG Iron
Material Stator SG Iron