Specifications

Cooling Method Water Cooling
Power Supply Voltage 3Ph 200V 50/60Hz

COOLPAK 5000 e LV - 2 CP (2x COOLVAC eSL or 2x COOLPOWER e by using 2x COOL.DRIVEi)

Part Number: 840000E5222

Contact us for availability

Click For Availability

Cryo Technology

Cryogenic systems are widely used in the vacuum industry for their ability to achieve ultra-low temperatures and create high vacuum conditions. These systems consist of a compressor unit and a cryogenic refrigerator, which work together to generate a cold environment. Cryogenic pumps are also used for vacuum operations, offering high pumping speeds and low ultimate pressures. Cryogenic technology is popular in industries such as semiconductor manufacturing, scientific research, and space exploration

 

LEYBOLD CRYOGENIC SYSTEMS - Intelligent. Smart. Economical

 

With regard to the increasing requirements of the market, Leybold fulfils the expectations of customers with its new range of cryogenic systems combining performant components. The cryogenic systems offer a great range of economical products which can be easily combined to meet your application's requirements.

 

The Leybold cooling systems consist of: COOLPAK e: Compressor unit & COOLPOWER e: Cryogenic refrigerator

 

The cryogenic pump systems consist of: COOLPAK e: Compressor unit & COOLVAC e: Cryogenic pump

COOLPAK 5000 e LV - 2 CP (2x COOLVAC eSL or 2x COOLPOWER e by using 2x COOL.DRIVEi)

Is the low volts variant of the COOLPAK 5000 i compressor family. It can operate and control up to two cryogenic pumps of type COOLVAC iSL or up to two COOLPOWER i cold heads by using an additional COOL.DRIVE i. It can also operate up to two COOLPOWER i cold heads or COOLVAC iBL pumps.

General Product Information

Cooling Method Water Cooling
Dimension Length 0.666
IP Rating IP40
Noise / Sound Level 60.00 db(A)
Power Supply Frequency 50 Hz
60 Hz
Power Supply Phase 3-Ph
Power Supply Voltage 3Ph 200V 50/60Hz
Dimension Comments The dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models.
Connection Inlet / Outlet Flange |
Connection Helium Aeroquip 1/2" male (Aeroquip series 5400-8b)
Helium Filling Pressure 1.600 × 10⁶

Environmental Conditions

Temperature Ambient Operation Max 40.00
Temperature Ambient Storage Max 65.00
Temperature Ambient Operation Min 5.00
Temperature Ambient Storage Min -20.00

Classification

Classification Dry or Wet Pump Dry
Classification High / Medium / Rough Vacuum pump High Vacuum Pump
Classification Vacuum Pump Technology Cryogenic Helium Compressor

Operation Conditions - Limitations

Altitude Max 2000.00
Product Title Part Number Add to cart
Cable Power Mains - COOLPAK i EU - 3m 840120V03
Cable Power Mains - COOLPAK i US - 3m 840120V03US
Cable Power Mains - COOLPAK i EU - 10m 840120V10
Cable Power Mains - COOLPAK i EU - 20m 840120V20
Cold Head Control Cable - 5 m 842115V05
Cold Head Control Cable - 10 m 842115V10
Cold Head Control Cable - 20 m 842115V20
Flexline FL 18.0 HP - 18m (1/2") (for pneumatically driven coldheads) 840203
Flexline FL 18.0 LP - 18m (1/2"/1/2") (for pneumatically driven coldheads) 840204
Set of Flexlines 4.5 - 4.5m (1/2", 1/2") (for pneumatically driven coldheads) 89287
Set of Flexlines 9.0 - 9m (1/2", 1/2") (for pneumatically driven coldheads) 89288
Flexline with Elbow Connector 1.0 HP - 1m (1/2") 840205
Flexline with Elbow Connector 1.0 LP - 1m (1/2") 840206
Flexline FL 20.0 LP - 20m DN16 (8F/8F) 840231
Earthquake Fixation - COOLPAK i (CP 5000i) 840131
Flexline FL 9.0 HP - 9m DN20 - (8F/8F) (for mechanically driven coldheads; 250MDi, 10MDi, 4MDi) 840217
Flexline FL 20.0 HP - 20m DN20 (250MDi, 10MDi, 4MDi) 840230V2020
Flexline FL 9.0 LP - 9m DN32 - (8F/8F) (1/2") (for mechanically driven coldheads; 250MDi, 10MDi, 4MDi) 840218V0032
Trolley helium compressor 840130
He Buffer Volume - 10l (1/2"M, 8M) 840270V10
Flexline with Elbow Connector 20.0 LP - 20m DN20 (8F-ELB 8F) 840230V0020
Gas Distributor GD2 - (1/2"F, 2x 1/2"M dual) 840253
Set of Flexlines with Elbow Connector (non standard) 0.65 - 0.65m DN12 (1/2", 1/2") (for pneumatically driven coldheads, Coherent) 840225V0007
Flexline FL 20.0 HP - 20m DN16 (8F/8F) 840230
Elbow Connector 90° - (1/2"F/1/2"M) 89173
Line coupling Flexline - (1/2"M, 1/2"M) 89171
COOL.DRIVE i 6543801
COOLPOWER 5/100e – DN 160 ISO-K 842100E06
COOLPOWER 140e - DN 130 W 842140E00
COOLPOWER 140e - DN 160 CF-R 842140E03
COOLPOWER 140e - DN 160 ISO-K 842140E06
COOLVAC 5000 eSL – DN 400 ISO-K 844402E0206
COOLVAC 10000 eSL - DN 500 ISO-F 844502E0005
COOLVAC 10000 eSL - DN 500 ISO-K 844502E0006
Pump Controller Cable - 5m 844120V05
Pump Controller Cable - 10m 844120V10
Pump Controller Cable - 20m 844120V20
COOLPOWER 250 MDe 842250E00
COOLPOWER 250 MDe - DN 160 ISO-K 842250E06
COOLPOWER 250 MDe - DN 160 CF-R 842250E03
Product Title Part Number Add to cart
COOLVAC 5000 eSL - DN 400 CF 844402E0002
COOLVAC 5000 eSL – DN 400 ISO-K 844402E0206
COOLVAC 10000 eSL - DN 500 ISO-F 844502E0005
COOLVAC 10000 eSL - DN 500 ISO-K 844502E0006