| Short Description | Part Number | Dimension Height | Dimension Length | Dimension Width | Weight | Connection Purge Gas, Gas Ballast, Vent | Power Total Rated @50Hz | Power Total Rated @60Hz | Pumping Speed Air Nitrogen 50Hz | Lubricant Capacity Min | Default Oil Type |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 14802120HG00CJL | 1.17 | 1.24 | 0.932 | 530.00 | 1 1/2" BSPP (or G 1 1/2") Female | 8000.00 | 8000.00 | 0.333 | 1.300 × 10⁻³ | LEYBONOL LVO 130 | |
| 14802120HG08CJL | 1.29 | 1.21 | 1.01 | 540.00 | - | - | - | - | - | - |
Dry Screw Pumps
VDs1200 is composed by WAU1001 , VD200, Stainless steel silencer, Non-return valve, 7"HMI , purge kit for VD . Each VDs1200 is default equipped with Electrical Cabinet with HMI , VFD for WAU1001 , soft starter and other eletrical components inside.
VDs1200 offers preventive maintenance via proactive monitoring VD operating hours , active remind belt change for VD200.
VDs1200 is a full dry system, either WAU1001 or VD200 are air-cooled. This system is best for facility with poor cooling water condition or applications limited by cooling water volume or temperature.
VARODRY
VDs1200 variants
-standard
-dusty application
VDs1200 dusty application version with default interstage gas filter to protect VD200 from clogged and extend operating hours.
Features and Benefits
- Benefits -Low cost of ownership -full air-cooled pump system -VFD driven , energy saving potential -7"HMI, easy for field configuration -soft starter, extra protection to incorrect wiring -Industrial grade gas filter , low pressure drop
General Product Information
| Connection Outlet Flange | DN 40 ISO-KF (NW40) |
| Connection Inlet Flange | DN 100 ISO-K |
| Cooling Method | Air Cooling |
| Dimension Height | 1.17 |
| Dimension Length | 1.24 |
| Dimension Width | 0.932 |
| Noise / Sound Level | 75.00 db(A) |
| Power Supply Phase | 3-Ph |
| Power Supply Voltage | 3Ph 400V ± 10%, 50/60 Hz |
| Weight | 530.00 |
| Connection Inlet / Outlet Flange | DN 100 ISO-K | DN 40 ISO-KF (NW40) |
| Connection Purge Gas, Gas Ballast, Vent | 1 1/2" BSPP (or G 1 1/2") Female |
Performance Data
| Power Total Rated | 8000.00 |
| Power Total Rated @50Hz | 8000.00 |
| Power Total Rated @60Hz | 8000.00 |
| Pressure Ultimate | 0.500 |
| Pumping Speed Air Nitrogen 50Hz | 0.333 |
| Pressure Backing Max | 1.200 × 10⁵ |
Operation Conditions - Limitations
| Lubricant Capacity Min | 1.300 × 10⁻³ |
| Lubricant Capacity Max | 1.300 × 10⁻³ |
| Pressure Permissible Purge Gas - Min and Max |
2.000 × 10⁵
2.000 × 10⁵ |
Environmental Conditions
| Temperature Ambient Operation Max | 40.00 |
| Temperature Ambient Operation Min | 0.000 |
Variants
| Lubricant used in Mechanical Booster Pump | LEYBONOL LVO 130 |
| Variant Enclosure Type | Partial |
Lubricants